Icom IC-T10
Compliance Test
Compliance testing to ascertain if this radio meets ITU guidelines for spurious emissions.
Icom IC-T10 Final Grade: PASS
The Icom IC-T10 amateur radio sample we tested performed exceptionally well across all bands. We measured no spurious emissions exceeding the levels permitted by ITU guidelines.
It is important to note that this was a single-sample test and it is possible other samples could vary in performance.
Discuss this radio on our forums. https://forums.advancedamateur.ca/t/icom-ic-t10
Power Output Testing
Power output was measured using a Surecom SW-33 Plus into a dummy load. The radio was set to maximum power. The ITU guidelines for spurious emissions require measurements of "the power (W) supplied to the antenna transmission line". That requirement makes this separate power measurement necessary, as it is incorrect to measure relative to the fundamental (f0). All numbers have been rounded.
2M
146.520 Mhz
4.8 watts
70cm
446.000 Mhz
5.0 watts
Spurious Emissions Testing
Spurious emissions were measured using a Tiny SA Ultra. The radio was set to maximum power and was connected to the TinySA through an attenuator. It is important to understand that the graphs below are using a decibel scale, not a linear scale. If a spurious emission spike appears to be almost as tall as the fundamental, that does not mean it is emitting almost as much power. Refer to the raw data shown.
VHF 2m Band Test Results: PASS
Raw Data 2m
All numbers have been roundedPower at Antenna: 36.8 dBm (4.8 watts)
Fundamental (f0): 36.2 dBm (4.2 watts)
The Icom IC-T10 sample that we tested displayed no significant spurious emissions above the 2 m band fundamental in our testing. All spurious emissions were at least 58.6 dB down from the power at the antenna, which is fully compliant with ITU guidelines.
UHF 70cm Band Test Results: PASS
Raw Data 70cm
All numbers have been roundedPower at Antenna: 37 dBm (5.0 watts)
Fundamental (f0): 35.8 dBm (3.8 watts)
The Icom IC-T10 sample that we tested displayed no significant spurious emissions above the 70 cm band fundamental in our testing. All spurious emissions were at least 58.7 dB down from the power at the antenna, which is fully compliant with ITU guidelines.
Comments
No surprises here.
Many thanks to Darryl VA7CQD for the use of this radio for testing.
~Reg Natarajan VA7ZEB / HJ1ZEB, August 31, 2024
Discuss this radio on our forums. https://forums.advancedamateur.ca/t/icom-ic-t10